Hydrofluoroethers 7100 and 7200 are designated as Acceptable (can be used without restrictions) as cleaning agents and refrigerants on the list of alternatives to Freon (SNAP list) determined by the U.S. Environmental Protection Agency (EPA), and have been excluded from volatile emissions by the EPA. Among organic compounds (VOC), they are mainly used in manufacturing industries such as precision electronic instruments and high-end medical equipment.
Product number: HFE 7100/7200/7300/7500
CL7200 [NOVEC 7200 replacement product]
Application recommendations: cleaning light dirt, refrigerants, solvents
Comparison of environmental performance of cleaning agents | |||
ODP | GWP | Atmospheric life unit: year | |
CL7100 | 0 | 320 | 4.1 |
CL7200 | 0 | 55 | 0.77 |
HFE-S7 | 0 | 580 | N/A |
HFC-4310mee | 0 | 1640 | 17.1 |
HFC-365mfc | 0 | 794 | 10.8 |
HCFC-225a | 0.03 | 180/620 | 2.1/6.2 |
HCFC-141b | 0.11 | 700 | 9.2 |
Typical properties of hydrofluoroether | ||||||
CL7100 | CL7200 | CL7300 | CL7500 | |||
Material description
|
Ingredients | C4F9OCH3 | C4F9OC2H5 | C6F13OCH3 | C7F15OC2H5 | |
Molecular weight | g/mol | 250 | 264 | 350 | 414 | |
Purity | 99.9% | 99.5% | 99.5% | 99.5% | ||
Non-volatile substance content | ppm | <2.0 | <1.0 | <1.0 | <1.0 | |
Appearance | colorless and transparent | colorless and transparent | colorless and transparent | colorless and transparent | ||
Physical and chemical properties |
boiling point | ℃ | 61 | 76 | 98 | 128 |
pour point | ℃ | -135 | -138 | -38 | -100 | |
Critical temperature | ℃ | 195 | 210 | 243 | 261 | |
critical pressure | Mpa | 2.23 | 2.01 | 1.88 | 1.55 | |
critical pressure | mmHg | 202 | 109 | 45 | 16 | |
latent heat of evaporation | KJ/Kg | 112 | 119 | 102 | 89 | |
liquid density | g/cm3 | 1.520 | 1.430 | 1.660 | 1.614 | |
Coefficient of expansion | K-1 | 0.0018 | 0.0016 | 0.0013 | 0.0013 | |
dynamic viscosity | cSt | 0.38 | 0.41 | 0.71 | 0.77 | |
absolute viscosity | mPa·S | 0.58 | 0.58 | 1.18 | 1.24 | |
Specific heat capacity | J/Kg-K | 1183 | 1220 | 1140 | 1128 | |
Thermal conductivity | W/m-K | 0.069 | 0.068 | 0.063 | 0.065 | |
Surface Tension | dynes/cm | 13.6 | 13.6 | 15.0 | 16.2 | |
Water solubility | ppmw | 95 | 92 | 67 | 45 | |
water soluble | ppmw | 12 | <20 | <1 | <3 | |
Dielectric strength 0.1″gap | kV | >25 | >25 | >25 | >25 | |
Dielectric constant @1kHz | - | 7.52 | 7.35 | 6.14 | 5.8 | |
Volume resistivity | Ohm-cm | 108 | 108 | 1011 | 2.2×108 | |
Environmental protection and safety
|
Ozone depletion potential (ODP) | 0 | 0 | 0 | 0 | |
Greenhouse effect potential GWP | 320 | 55 | 200 | 90 | ||
Atmospheric lifetime | Year | 4.1 | 0.77 | 3.8 | 2.2 | |
Flash point | ℃ | none | none | none | none | |
Flammability range in air | none | 2.4–12.4% | none | none | ||
Safe exposure limit TWA | ppm | 750 | 200 | 100 | 100 | |
Note: ODP (Ozone Depleting Potential): The ozone depleting potential value of CFC-11 (Freon 11) is 1. If the value is greater than zero, it indicates damage to ozone. GWP (Global Warming Potential): The global warming potential coefficient of carbon dioxide is 1, accumulated for 100 years Atmospheric lifetime: calculated based on the reactivity between hydroxyl and oxygen radicals, indicating the lifetime of a substance in the atmosphere. Safe exposure limit (TWA): Most workers must work at this concentration during eight hours a day and 40 hours a week, otherwise adverse reactions harmful to health will occur. The larger the value, the safer and lower the toxicity of the solvent. |
packing
25kg